DURKOPP ADLER 512 Service Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 74
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
Settings via software
Service manual 512/532 Version 00.0 - 12/2013 39
11.11Counter
The counter can be used as a unit counter (parameter number U020) or as
an automatic stop counter (parameter number U076).
Prerequisite:
The machine is in the programming mode, the LED in the Ready button
is off.
1. Press the Selection button until the Counter LED illuminates.
2. Press the Reset button to set the counter to 0.
3. Press the +/- Function buttons to set the cycle count.
Each sewing end decrements the counter by 1.
After reaching the number of cycles, a message appears in the display.
4. Insert a new bobbin.
5. Press the Reset button.
The counter is reset.
11.12Interrupting sewing
1. Press the Reset button or press the pedal back.
The sewing process is interrupted; the display shows error message
E-50.
2. To continue sewing, press the Reset button or press the pedal forwards.
11.13Protecting standard sewing patterns
Standard sewing patterns can be protected so that they are no longer
displayed.
Prerequisite:
The machine is in the programming mode, the LED in the Ready button
is off.
1. Press the Memory and P1 buttons in quick succession.
The Program display shows the sewing pattern number; the Function
display shows 0 or 1:
0 = sewing pattern is displayed.
1 = sewing pattern is protected.
2. Press the +/- Program buttons to select another sewing pattern.
3. Press the Ready button to confirm the sewing pattern.
4. Press the +/- Function buttons to change between 0 and 1.
5. Press the Ready button to confirm the value.
6. Press the Memory button.